1 / 5
Model No. : | YJV |
---|---|
Brand Name : | HUAYUAN YONGTONG |
Type : | Insulated |
Beijing, Beijing, China
Descrizione del prodotto
1. STANDARD APPLICATIVI
Il cavo che Pechino Huayuan Gaoke Cable Co., Ltd. offerto deve essere progettato, fabbricato e testato secondo le norme internazionali come segue:
Quality Control Standard |
|
ISO 9001 |
Quality Management Systems |
ISO 14001 |
Environmental Management Systems |
Component Material Standard |
|
IEC 60228 |
Conductors of insulated cables |
Cable Standard |
|
IEC 60502-1 |
Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3kV(Um=3.6kV) Fire retardant according to IEC/EN 60332-3-24 |
2.
CABLES STRUCTURE XLPE C ABLE
1 )
CU / XLPE / PVC 0,6 / 1 kV 1 × 50 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular copper conductor |
/ |
8.1 |
2 XLPE insulation |
1.0 |
10.1 |
3-FR-PVC Outer sheath |
1.4 |
12.9 |
2)
CU / XLPE / PVC 0.6 / 1kV 1 × 95 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular copper conductor |
/ |
11.5 |
2 XLPE insulation |
1.1 |
13.7 |
3-FR-PVC Outer sheath |
1.5 |
16.7 |
3)
CU / XLPE / PVC 0.6 / 1kV 4 × 16 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded non-compacted circular copper conductor |
/ |
5.0 |
2 XLPE insulation |
0.7 |
6.4 |
3 Filling |
/ |
15.5 |
4 Wrapping tape |
0.2 |
16.1 |
5-FR-PVC Outer sheath |
1.8 |
19.7 |
4)
CU / XLPE / PVC 0.6 / 1kV 4 × 25 mm 2
Construction |
Nominal Thickness(mm) |
Nominal Diameter(mm) |
1-Stranded compacted circular aluminum conductor |
/ |
5.9 |
2 XLPE insulation |
0.9 |
7.7 |
3 Filling |
/ |
18.6 |
4 Wrapping tape |
0.2 |
19.2 |
5-FR-PVC Outer sheath |
1.8 |
22.8 |
3. Particolari tecnici garantiti
1) CU / XLPE / PVC 0,6 / 1 kV 1 × 50 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
50 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
1×50mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
8.1 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
gray |
11 |
Nominal thickness of insulation |
mm |
1.0 |
12 |
Nominal diameter over insulation |
mm |
10.1 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.4 |
17 |
Nominal overall diameter of cable |
mm |
12.9 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
7.3(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
458 |
21 |
Minimum bending radius |
mm |
230 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.387 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
325( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
230(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
2) CU / XLPE / PVC 0.6 / 1kV 1 × 95 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
95 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
1×95mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
11.5 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
gray |
11 |
Nominal thickness of insulation |
mm |
1.1 |
12 |
Nominal diameter over insulation |
mm |
13.7 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.5 |
17 |
Nominal overall diameter of cable |
mm |
16.7 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
13.8(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
919 |
21 |
Minimum bending radius |
mm |
300 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.193 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
370( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
335(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
3) CU / XLPE / PVC 0.6 / 1kV 4 × 16 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
16 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
4×16mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded non-compacted circular |
9 |
Nominal diameter of conductor |
mm |
5.1 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
Black, Blue, Brown, Gray |
11 |
Nominal thickness of insulation |
mm |
0.7 |
12 |
Nominal diameter over insulation |
mm |
6.4 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.8 |
17 |
Nominal overall diameter of cable |
mm |
19.7 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
2.4(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
721 |
21 |
Minimum bending radius |
mm |
300 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
1.15 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
75( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
92(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
4) CU / XLPE / PVC 0.6 / 1kV 4 × 25 mm 2
No |
DESCRIPTION |
UNIT |
VALUEREQUIRED |
1 |
Manufacturer |
|
BEIJING HUAYUAN |
2 |
Cable size |
mm2 |
25 |
3 |
Cable type |
|
CU/XLPE/PVC |
4 |
Voltage Grade |
kV |
0.6/1(1.2) |
5 |
Reference Standard |
|
IEC 60228 IEC 60502.1 |
6 |
No. and cross sectional area of conductor |
|
4×25mm2 |
7 |
Conductor material |
|
Copper |
8 |
Shape |
|
stranded compacted circular |
9 |
Nominal diameter of conductor |
mm |
5.9 |
10 |
Insulation material |
|
XLPE |
|
Colour |
|
Black, Blue, Brown, Gray |
11 |
Nominal thickness of insulation |
mm |
0.9 |
12 |
Nominal diameter over insulation |
mm |
7.7 |
13 |
Inner sheath material |
|
NA |
14 |
Nominal thickness of inner sheath |
mm |
NA |
15 |
Outer sheath material |
|
ultraviolet-proof-FR-PVC |
|
Colour |
|
gray |
16 |
Nominal thickness of outer sheath |
mm |
1.8 |
17 |
Nominal overall diameter of cable |
mm |
22.8 |
18 |
Short circuit current rating(t=1.0sec) |
|
|
|
Of conductor |
kA |
3.7(max) |
19 |
Max. conductor temperature in short circuit |
℃ |
250(not exceed 5s) |
20 |
Approx. weight of cable |
kg/km |
1063 |
21 |
Minimum bending radius |
mm |
340 |
22 |
Max.D.C. Conductor resistanceat20`C |
Ω/km |
0.727 |
23 |
Max. conductor temperature on continuous |
℃ |
90 |
24 |
Max. current rating in air |
A |
92( temperature 40° C , 1 circuit, flat formation, phase distance 2 diameter of cable) |
25 |
Max. current rating in tunnel |
A |
126(depth of laying 1000 mm ,thermal resistivity of soil 1.2 k.m/W,temperature 25℃, flat formation, phase distance 2 diameter of cable) |
4 . REQUISITI DI PROVA PER I CAVI DI ALIMENTAZIONE
La prova del cavo deve essere eseguita in conformità con lo standard applicabile dei cavi di alimentazione 0.6 / 1kV. Le seguenti voci di prova devono essere eseguite conformemente alle norme IEC pertinenti.
No. |
Test item |
Routine tests |
|
1 |
measurement of the electrical resistance of conductors |
2 |
Voltage test |
Sample tests |
|
1 |
conductor examination |
2 |
check of dimensions |
3 |
Hot set test for XLPE insulation |
5 . INFORMAZIONI imballaggio per 0 0,6 / 1 kV CAVO P OWER
I cavi devono essere avvolti su tamburi di legno-acciaio. La marcatura indelebile deve essere stampata sulla superficie della flangia del tamburo in base alle esigenze del cliente.
Cable Type |
Drum length(m) |
Drum Dimensions (mm) |
|||
D |
d |
L2 |
L1 |
||
CU/XLPE/PVC 0.6/1kV-1C*50mm2 |
1000 |
1000 |
450 |
450 |
550 |
CU/XLPE/PVC 0.6/1kV-1C*95mm2 |
1000 |
1250 |
690 |
580 |
700 |
CU/XLPE/PVC 0.6/1kV-4C*16mm2 |
500 |
1250 |
690 |
580 |
700 |
CU/XLPE/PVC 0.6/1kV-4C*25mm2 |
500 |
1250 |
690 |
580 |
700 |
Nota: il valore [D "non deve contenere la dimensione delle piastre di tenuta.
La nostra fantasia
Pacchetto
Consegna
Onore
La tensione del cavo di allarme antincendio, il cavo di allarme antincendio di sicurezza, il cavo a prova di fuoco, il cavo di resistenza al fuoco possono essere tutti 0,6 / 1kv o 1kv o 0,6 kv.
Beijing, Beijing, China
Invia la tua richiesta a questo fornitore