1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO
1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO

1 / 5

1 × 400/35 mm2 CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV CAVO

Ottieni l'ultimo prezzo
Invia richiesta
Model No. : YJY62
Brand Name : HUAYUAN YONGTONG
Type : Insulated
Conductor Type : Stranded
Application : Underground
Conductor Material : Copper
Sheath Material : Crosslinking
Insulation Material : XLPE
Material Shape : Round Wire
Certification : ISO9001
Brand : HUAYUAN YONGTONG
Di più
8yrs

Beijing, Beijing, China

Visita il negozio
  • Certificazione della piattaforma
  • video

Descrizione del prodotto

1. STANDARD APPLICATIVI

Il cavo che Pechino Huayuan offre deve essere progettato, fabbricato e testato secondo le norme internazionali come segue:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 60502-2

Power cables with extruded insulation and their  accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) –

Part 2:Cables for rated voltages from 6 kV (Um = 7,2 kV)

up to 30 kV (Um = 36 kV)


2.CABLES STRUCTURE per cavo 1C * 400mm2

cable1



CU / XLPE / CWS / PVC / AWA / PVC 18/30 (36) kV 1 × 400/35 mm2

Construction

Nominal Thickness(mm)

Nominal Diameter(mm)

1- Stranded compacted circular copper conductor

/

23.2

2- Conductor screen

0.8

24.8

3- XLPE insulation

8.0

40.8

4- Insulation screen

0.6

42.0

5- Semi-conductive water-blocking tape

0.3

42.3

6- Copper wire with copper tape screen

Nominal cross section 35mm2

44.6

7- Wrapping tape

0.2

45.2

8- PVC inner sheath

1.5

48.2

9- Aluminum wire armour

2.5

53.2

10-Wrapping tape

0.25

54.7

11-PVC Outer sheath

2.8

60.3


3. Particolari tecnici garantiti

N2XSYRY

18/30 KV Power Cable- CU/XLPE/SCRlBDlAWAlPVC

Size 1x400 Sqmm

Size 1x400 Sqmm





Item

Description

Specification

offer

1

No. ofCores

1

1

2

Conductor Material

Cu

Cu

3

Conductor size

400 mm²

400 mm²(nominal)

4

No. And diameter of wires (No/mm)

61x2.85

60x2.97(nominal)

5

Conductor Diameter

~22.5 mm

23.2mm(nominal)

6

Thickness of inner semi-conductor layer

~ 0.8 mm

0.8mm(nominal)

7

Diameter over inner semi-conductor layer

~22 mm

24.8mm(nominal)

8

Insulation material

XLPE

XLPE

9

THickness of insulation, nominal

~6 mm

8.0mm(nominal)

10

Diameter over insulation,nominal

~33 mm

40.8mm(nominal)

11

Thickness of outer semi-conductor layer

~0.5 mm

0.6mm(nominal)

12

Diameter  of outer semi-conductor layer

35 mm

42.0mm(nominal)

13

Semi-conductor & water blocking tape thickness

0.3 mm

0.3mm(nominal)

14

Nominal crosssection of screen

35 mm²

35 mm²

15

Screen specification

Copper wire &copper tape applied helically

Copper wire &copper tape applied helically

16

Specification sheath material

PVC (ST2)

PVC (ST2)

17

Thickness of separation sheet

~ 40 mm

1.5mm(nominal)

18

Diameter of armour wires

Alumininum & 2.5 mm

2.5(nominal,AL wire)

19

Diameter of over amouring

 ~ 44 mm

53.2(nominal)

20

Outer sheet material

PVC (ST2)

PVC (ST2)

21

Thickness of outer sheath, nominal

2.5 mm

2.8 mm(nominal)

22

Overal diameter

~50 mm

60.3(nominal)

23

AC test voltage for 5 min (For fisrt time)

70 KV

70 kV

24

Cable color

Red

red


4. REQUISITI DI PROVA PER Cavi elettrici MT

La prova del cavo deve essere eseguita in conformità con lo standard applicabile dei cavi di alimentazione 18 / 30kV. Le seguenti voci di prova devono essere eseguite conformemente alle norme IEC pertinenti.

No.

Test item

Routine tests

1

measurement of the electrical resistance of conductors

2

Partial discharge test

3

Voltage test

Sample tests

1

conductor examination

2

check of dimensions

3

Voltage test for 4 h

4

Hot set test for XLPE insulation



La nostra azienda

Factory-1


laboratorio


undefined

Pacchetto

undefinedundefined

Consegna e pagamento

undefined

undefined


Onore

undefined

Ora cliente

undefined


1.Tre core conduttore in rame 2. Cinque conduttori in rame conduttore 3. Cavo di alimentazione ad alta tensione 4. Cavo 33kv 5. Cavo di costruzione 6. Cavo in acciaio rivestito con cavo 7.Tenitore in acciaio satinato

Invia richiesta

Avviso prodotto

Iscriviti alle tue parole chiave interessate. Invieremo gratuitamente i prodotti più recenti e più caldi alla tua casella di posta. Non perdere nessuna informazione commerciale.